Mac Studio (2023) Speaker
Before You Begin
Remove the following parts before you begin:
Tools
Adjustable torque driver (10–34 Ncm)
ESD-safe tweezers
Nylon probe (black stick)
Torx Plus 5IP 50 mm bit
Removal
Use the adjustable torque driver and Torx Plus 5IP bit to remove the two 5IP screws (923-09160) from the speaker.
Slightly lift the speaker. Use the flat end of the black stick to lift the end of the speaker flex cable off the connector on the logic board.
Lift the speaker out of the housing.
Reassembly
Position the speaker over the logic board.
Use the flat end of the black stick to press the end of the speaker flex cable to the connector (1).
Align the screw holes in the speaker with the two speaker standoff screws on the logic board (2).
Set the torque value of the adjustable torque driver to 13 Ncm. Then use the adjustable torque driver and Torx Plus 5IP bit to reinstall the two 5IP screws (923-09160) into the speaker.
Reinstall the following parts to complete reassembly: