Studio Display VESA Mount Adapter
Before You Begin
Danger
Ensure that the power cord is not plugged into an electrical outlet.
Remove the following parts before you begin:
Tools
- Adjustable torque wrench (2.5–25 Nm) 
- Alignment pins for stand and VESA mount adapter 
- Torx Plus 20IP 70 mm bit 

Removal
- Lay the display flat on a table. 
- Insert the 20IP bit into the 2.5–25 Nm adjustable torque wrench. Use the adjustable torque wrench and 20IP bit to remove the seven 20IP screws (452-06742).  
- Lift the housing from the mount.  
Reassembly
Important
- If you’re installing a replacement VESA mount adapter, use the screws included with the replacement VESA mount adapter. 
- To replace the VESA mount adapter with a tilt-adjustable stand, follow the reassembly steps in Tilt-Adjustable Stand. 
- To replace the VESA mount adapter with a tilt- and height-adjustable stand, follow the reassembly steps in Tilt- and Height-Adjustable Stand. 
- Insert the flange into the mount adapter.   
- Install two alignment pins into the flange as shown.  
- Use the alignment pins to position the display onto the mount adapter.  
- Use the 2.5–25 Nm adjustable torque wrench and 20IP bit to partially reinstall five 20IP screws (452-06742) in the order shown.  
- Keep the 20IP bit in the 2.5–25 Nm adjustable torque wrench. Set the torque value to 3.1 Nm. 
- Use the adjustable torque wrench and 20IP bit to fully reinstall the five 20IP screws in the order shown.  
- Remove the two alignment pins. Ensure that the 2.5–25 Nm adjustable torque wrench is still set to 3.1 Nm. 
- Use the adjustable torque wrench and 20IP bit to fully reinstall the two 20IP screws as shown.  
Reinstall the following parts to complete reassembly: