Learn what it means if the power light flashes twice when you try to start up your server.

Products Affected

Xserve

Symptom

The server does not start up; the power light flashes twice when you try to start the server. The flashes repeat every 5 seconds.

Products affected

  • Xserve G5


Solution

When the power light flashes twice, this means that incompatible RAM is probably installed.

Install memory

Install the correct memory:


Xserve G5 PC3200 DDR


Check the installed memory

  1. Check that the memory is installed in pairs, as described in the User's Guide.
  2. Try removing the memory in pairs and testing again, to isolate any possible bad DIMMs.
  3. If all DIMMs are known good memory and the issue still occurs, the logic board may need to be replaced.


Note: When installing the replacement logic board, make sure the ports and ID button on the back of the board align with the opening in the chassis.