Archived - Xserve (Slot Load): Power Consumption and Thermal Output (BTU) Information

This document provides power consumption and thermal output information for Xserve (Slot Load) computers.
This article has been archived and is no longer updated by Apple.
Xserve (Slot Load) single processor "minimum" configuration
Configuration: 1.33 GHz G4 Processor, 1 GB RAM, 60 GB Apple Drive Module,
(2) gigabit Ethernet ports, CD-ROM, VGA Display
Power Consumption Thermal Output
Idle Max Idle Max
92 W 94 W 314 BTU/h 321 BTU/h
Xserve (Slot Load) single processor "maximum" configuration
Configuration: 1.33 GHz G4 Processor, 1 GB RAM, one 60 GB and three 120 GB
Apple Drive Modules, (2) gigabit Ethernet ports, ATI Radeon 7500 Graphics card (ADC/VGA),
CD-ROM, 2 PCI cards
Power Consumption Thermal Output
Idle Max Idle Max
145 W 187 W 496 BTU/h 639 BTU/h
Xserve (Slot Load) dual processor "minimum" configuration
Configuration: Dual 1.33 GHz G4 Processor, 1 GB RAM, 60 GB Apple Drive Module,
(2) gigabit Ethernet ports, VGA display, CD-ROM
Power Consumption Thermal Output
Idle Max Idle Max
133 W 134 W 453 BTU/h 459 BTU/h
Xserve (Slot Load) dual processor "maximum" configuration
Configuration: Dual 1.33 GHz G4 Processor, 1 GB RAM, one 60 GB and three 120 GB
Apple Drive Modules, (2) gigabit Ethernet ports, ATI Radeon 7500 Graphics card (ADC/VGA),
CD-ROM, 2 PCI cards
Power Consumption Thermal Output
Idle Max Idle Max
188 W 244 W 642 BTU/h 833 BTU/h

Notes:

1. Max in table is maximum processor utilization.

2. 180GB Apple Drive Modules use the same power consumption and thermal output as 120GB modules.

Last Modified: Feb 20, 2012